Technical Support
(877) SEPAX-US, press 3 TechSupport@sepax-tech.com |
|
By Separation Mode | By Brand | By Sample Based Application | |
Size Exclusion Ion Exchange Hydrophobic Interaction Ion Exclusion Sub-2 UHPLC Purification Reversed Phase Mixed-mode Phase HILIC View All |
SEC-MALS Unix / Unix-C Zenix / Zenix-C SRT / SRT-C SRT-10 / SRT-10C Proteomix HIC / IEX Antibodix Carbomix Proteomix RP View All |
ADC Antibody Biosimilar Carbohydrate Cell Lysate DNA/RNA Fusion Protein Glycan Glycoprotein Heparin |
Insulin Membrane Protein Organic Acid PEG/PEGylated Protein Peptide Polymer Protein Vaccine/VLP Others |
How May We Help You?
How May We Help You?
How May We Help You?
Your question has been submitted.
We will respond back to you shortly.
We will respond back to you shortly.
How May We Help You?
Please fill out all required fields.
Sample: PeptidePeptide Recommended products
Size Exclusion:
Zenix
Zenix-C
SRT
SRT-C
Preparative SEC
Ion Exchange: Proteomix Antibodix Reversed phase: Proteomix RP Bio-C4
|
Application Note
Featured Application Notes
All Application Notes
App ID | Title |
EE1005 | SEC Analysis of Insulin and HMW Aggregates | Size Exclusion@Size Exclusion@Size ExclusionZenix-CMethod Optimization@Pore Size Selection@Resolution@Lot to Lot@Sample Stability Test@Column Stability@AggregatesHPLC1
EE1002 | Exenatide Analysis on Zenix SEC-80 | Size ExclusionZenixExenatide AnalysisHPLC1
BE1004 | BE1004- Human serum albumin tryptic digest separation on reversed phase Bio-C18 | Reversed PhaseBio-C18Resolution@Method Optimization@Pore Size SelectionHPLC1
EE1006 | Glucagon SEC Separation in 45% Acetonitrile with 0.1% TFA | Size ExclusionZenix-CVolatile Buffer@Method Optimization@ResolutionHPLC@LCMS1
EE1004 | Insulin SEC Analysis | Size ExclusionZenix-CMethod Optimization@Pore Size Selection@Resolution@Lot to Lot@Sample Stability Test@Column Stability@AggregatesHPLC1
GA1001 | Amino Acids on GP-C18 | Reversed PhaseGP-C18Resolution@Volatile BufferHPLC@LCMS1
EE1003 | Transfer Factor Oral Solution SEC Separation | Size ExclusionZenix@Zenix-CParticle Size Impact@Pore Size Selection@Packing ChemistryHPLC1
PE1003 | Peptide Separation on Proteomix SCX | Ion ExchangeProteomixFast Assay@Method Optimization@Particle Size ImpactHPLC@UHPLC@NanoLC1
PE1002 | Analysis of Peptide Digest on Sub 2 µm Proteomix SCX | Ion ExchangeProteomixLoadingHPLC@UHPLC@NanoLC1
ZE1009 | Analysis of Exenatide and Pegylated Exenatide on Zenix and Zenix-C SEC | Size ExclusionZenix@Zenix-CPacking Chemistry@Aggregates@Volatile Buffer@ResolutionHPLC@LCMS1
PP1011 | Exenatide Acetate Analysis on Proteomix SCX | Ion ExchangeProteomixResolution@Volatile BufferHPLC@LCMS1
ZZ1009 | Zenix and Zenix-C SEC-80 for Peptide Analysis | Size ExclusionZenixVolatile Buffer@Packing Chemistry@Volatile BufferHPLC@LCMS@NanoLC1
BE1002 | Analysis on Microcystin on Bio-C18 | Reversed PhaseBio-C18Volatile BufferHPLC@LCMS1
BE1001 | Analysis of a Peptide on Bio-C18 | Reversed Phase@Bio-C18Volatile BufferHPLC@LCMS1
ZZ1007 | E.Coli Tryptic Digest on Zenix SEC-80 | Size ExclusionZenixResolutionHPLC1
ZZ10061 | Peptide Separations Using Zenix SEC-80 | Size ExclusionZenixMethod Optimization@ResolutionHPLC1
ZE1008 | Separation of 13.7 KD to 120 Da Peptide on Zenix-80 | Size ExclusionZenixResolutionHPLC2
ZE1007 | Analysis of E.coli Tryptic Digest on Zenix SEC-80 | Size ExclusionZenixResolutionHPLC2
ZE1006 | Four Peptide Mixture from 1kD to 6kD on Zenix SEC-80 | Size ExclusionZenixResolution@Volatile BufferHPLC@LCMS2
ZP1010 | Separation of Asparaginase on Zenix SEC-150 | Size ExclusionZenixResolution@AggregatesHPLC2
ZE1005 | Analysis of 5kD and 8kD Peptides by Zenix SEC-150 | Size ExclusionZenixResolutionHPLC2
ZE1004 | Competition Comparison for Peptide Separation on SEC | Size ExclusionZenixCompetition ComparisonHPLC2
ZE1002 | Analysis of Peptide Mixture on Zenix SEC -100 | Size ExclusionZenixResolution@Volatile BufferHPLC@LCMS2
SP1007 | Analysis of Insulin on SRT SEC-150 | Size ExclusionSRTAggregatesHPLC2
SE1001 | Separation of Peptide and Protein Mixture on SRT | Size ExclusionSRTPore Size SelectionHPLC2
PE1001 | Separation of Peptide on Proteomix SCX with Volatile Buffer | Ion ExchangeProteomixVolatile BufferHPLC@LCMS2
AE1001 | Gradient Impact on Peptide Analysis on Antibodix WCX | Ion ExchangeAntibodixMethod OptimizationHPLC2
ZE1012 | Separation of Peptides and Small Proteins using Zenix SEC-100 | Size ExclusionZenixColumn Stability@Resolution@AggregatesHPLC2